awesome-proteomics
Guides

Tool Compatibility Matrix

#reference#tools#compatibility#vendor-formats#file-formats

Which analysis tool can open which vendor's raw data, and on which operating system? This is one of the first practical questions in any project, because the answer decides whether you can search your files as-is or have to convert them first.

This page collects what the tool authors document, cross-checked against vendor sources. When a tool's own docs and a third-party claim disagree, the tool's own documentation wins here.

How to use this matrix: find the format you have (a column), then read down to see which tools read it natively. A πŸ”„ means "convert to mzML first" - see the File Format Cheat Sheet for what each format is and how to convert it.

TL;DR

  • Thermo .raw is the most broadly supported native format - almost every modern tool reads it directly.
  • Bruker timsTOF .d is read natively by the major DIA/timsTOF-aware tools (DIA-NN, FragPipe, MaxQuant, Spectronaut, Skyline, PEAKS).
  • SCIEX .wiff, Agilent .d, and Waters .raw have narrower native support; outside a few tools you convert them to mzML first.
  • mzML is the universal fallback. If a tool reads nothing else you have, convert to mzML and every search engine here will take it.
  • On Linux/macOS, native vendor reading is limited. Thermo .raw and Bruker .tdf/.tsf are the two formats that travel off Windows well; the rest usually means converting on a Windows machine (or via Wine/Docker) first.

The question this answers

Two files with the same science inside can need completely different handling depending on the instrument that produced them. A search engine that is perfect for your Thermo data may not open a SCIEX .wiff at all. This matrix is the lookup table for "can tool X open file Y, and where can I run it?"

It does not rank tools by quality or sensitivity - that belongs in tool-specific comparisons. This is purely about file and platform compatibility.

Legend

  • βœ… Reads the format natively (no conversion needed)
  • πŸ”„ Convert to mzML first (typically with ProteoWizard MSConvert)
  • 🟑 Partial / version- or module-dependent (see notes)
  • β€” Not supported, or not a typical input
  • πŸŽ“ Free for academic and non-profit use; commercial use needs a license
  • πŸ’° Paid for everyone

Matrix 1 - Native raw-format support

Tool Thermo .raw Bruker .d (timsTOF) SCIEX .wiff Agilent .d Waters .raw Open .mzML
FragPipe / MSFragger πŸŽ“ βœ… βœ… ^1 πŸ”„ πŸ”„ πŸ”„ βœ…
DIA-NN πŸŽ“ βœ… βœ… βœ… ^2 πŸ”„ πŸ”„ βœ…
MaxQuant βœ… βœ… βœ… βœ… πŸ”„ βœ…
MetaMorpheus βœ… πŸ”„ πŸ”„ πŸ”„ πŸ”„ βœ… ^3
Sage πŸ”„ 🟑 ^4 πŸ”„ πŸ”„ πŸ”„ βœ… ^5
Comet πŸ”„ πŸ”„ πŸ”„ πŸ”„ πŸ”„ βœ… ^6
OpenMS πŸ”„ ^7 πŸ”„ πŸ”„ πŸ”„ πŸ”„ βœ…
AlphaPept / AlphaDIA βœ… βœ… πŸ”„ πŸ”„ πŸ”„ βœ…
Skyline βœ… βœ… βœ… βœ… βœ… βœ… ^9
Spectronaut πŸ’° βœ… βœ… βœ… β€” βœ… βœ… ^8
Proteome Discoverer πŸ’° βœ… 🟑 ^10 🟑 🟑 🟑 βœ…
PEAKS Studio πŸ’° βœ… βœ… βœ… βœ… βœ… βœ… ^11

Notes

  1. FragPipe reads Bruker .d natively for ddaPASEF (timsTOF). Other Bruker .d acquisitions should be converted to mzML. timsTOF reading on Windows needs the Visual C++ 2017 redistributable installed.
  2. DIA-NN reads SCIEX .wiff only on Windows, and only after copying the ProteoWizard SCIEX/Clearcore .dll files into the DIA-NN folder. On native Linux builds DIA-NN supports .d, .raw, .mzML, and its own .dia only (no .wiff).
  3. MetaMorpheus also accepts .mgf. .mzML must be centroided.
  4. Sage began as an mzML-only engine; recent versions read Bruker timsTOF .d directly. Thermo .raw still needs converting to mzML first. If you are on an older build or hit trouble with .d, fall back to mzML.
  5. Sage also reads mzMLb (HDF5-backed mzML) and can stream compressed spectra from cloud storage.
  6. Comet also reads mzXML, .mgf, and .ms2.
  7. OpenMS works on mzML natively; convert vendor formats with MSConvert or ThermoRawFileParser first. It also ships its own conversion tools.
  8. Spectronaut additionally takes its HTRMS compressed format and supports dia-PASEF, SWATH, and FAIMS-DIA methods. Documented vendors: Thermo, SCIEX, Bruker, Waters.
  9. Skyline reads all major vendor formats natively on Windows through the bundled ProteoWizard libraries (Thermo, SCIEX WIFF1/WIFF2, Agilent, Waters, Bruker, Shimadzu), plus mzML/mzXML.
  10. Proteome Discoverer is Thermo-native; other vendors depend on installed nodes/modules and licensing, so treat non-Thermo support as version-dependent.
  11. Exact PEAKS vendor and instrument support depends on version and licensed modules; verify against the current PEAKS documentation for your release.

Matrix 2 - Platforms and interface

Tool Windows Linux macOS Interface License
FragPipe / MSFragger πŸŽ“ βœ… βœ… 🟑 GUI + CLI Free (academic)
DIA-NN πŸŽ“ βœ… βœ… β€” GUI (Win) + CLI Paid Enterprise; limited free Academia
MaxQuant βœ… βœ… β€” GUI (Win) + CLI Free
MetaMorpheus βœ… βœ… βœ… GUI + CLI Open source
Sage βœ… βœ… βœ… CLI Open source
Comet βœ… βœ… βœ… CLI Open source
OpenMS βœ… βœ… βœ… CLI + TOPPView GUI Open source
AlphaPept / AlphaDIA βœ… βœ… βœ… GUI + CLI Open source
Spectronaut πŸ’° βœ… β€” β€” GUI Commercial
Skyline βœ… 🟑 β€” GUI + CLI (SkylineCmd) Free
Proteome Discoverer πŸ’° βœ… β€” β€” GUI Commercial
PEAKS Studio πŸ’° βœ… β€” 🟑 GUI Commercial
  • DIA-NN licensing checked on: 2026-09-27. Enterprise is paid; the free Academia edition has limited features and is restricted to non-profit academic research. See the official edition and licensing information.
  • MaxQuant runs as a GUI on Windows and from the command line on Linux (via .NET/Mono).
  • FragPipe and MetaMorpheus run on macOS, but native vendor reading is most reliable on Windows/Linux; on macOS, plan to work from mzML.
  • Skyline is a Windows application; Linux/macOS use is typically through containers or remote Windows, not a native build.

The conversion hub: ProteoWizard / MSConvert

When native support runs out, almost everyone routes through ProteoWizard MSConvert. Per ProteoWizard's own documentation, the bundled vendor readers cover:

Vendor Formats MSConvert reads
Thermo Scientific .raw
Bruker Compass .d, YEP, BAF, FID, TDF, TSF
SCIEX WIFF / WIFF2
Agilent MassHunter .d
Waters MassLynx .raw / UNIFI
Shimadzu LCD (except ITOF)
AB T2D

It writes mzML, mzXML, MGF, and (recent versions) txt. The vendor readers require Windows and Microsoft .NET 4.8 or higher. On Linux/macOS, MSConvert is usually run via the official ProteoWizard Docker image (Wine under the hood).

Practical rule: when in doubt, convert to centroided mzML with MSConvert and feed that to any tool above.

Native reading on Linux and macOS

Two vendor formats travel off Windows cleanly, which matters for cluster and cloud pipelines:

  • Thermo .raw is read on Linux and macOS through Thermo's RawFileReader, a .NET library that runs under .NET or Mono. Tools that embed it, such as MetaMorpheus, FragPipe and MaxQuant, read .raw directly there, and ThermoRawFileParser uses it to convert .raw to mzML on any platform.
  • Bruker timsTOF .tdf/.tsf are readable on Linux because Bruker's TDF-SDK ships Windows and Linux builds. This is what lets DIA-NN, FragPipe, and MaxQuant read Bruker .d natively on Linux servers. Note TDF-SDK does not read the older .baf.

Everything else - SCIEX .wiff, Agilent .d, Waters .raw - depends on Windows-only vendor DLLs. On Linux/macOS, convert to mzML first (typically on a Windows box or via the ProteoWizard Docker image).

Quick decision guide

  • "I have Thermo .raw" - open it directly in FragPipe, DIA-NN, MaxQuant, MetaMorpheus, Spectronaut, Skyline, Proteome Discoverer, or PEAKS. For Comet or OpenMS, convert to mzML first.
  • "I have Bruker timsTOF .d" - DIA-NN, FragPipe (ddaPASEF), MaxQuant, Spectronaut, Skyline, and PEAKS read it natively; convert other acquisitions to mzML.
  • "I have SCIEX .wiff" - MaxQuant, Spectronaut, Skyline, and PEAKS read it natively. DIA-NN reads it on Windows with the SCIEX DLLs. Otherwise convert to mzML.
  • "I have Agilent .d" - MaxQuant, Skyline, and PEAKS read it natively; otherwise convert to mzML.
  • "I have Waters .raw" - Spectronaut, Skyline, and PEAKS read it natively; otherwise convert to mzML.
  • "I need open-source tools on Linux/macOS" - consider Comet, Sage, OpenMS, or MetaMorpheus with mzML input; check the platform and format tables above for native vendor readers. DIA-NN is available on Linux under the edition restrictions described above.

A note on completeness

This matrix is not exhaustive. It covers widely used tools and the most common vendor formats; it omits many specialized, top-down, metabolomics, and instrument-vendor tools. Format support also changes between versions - tools add native readers, vendors revise SDKs (for example the SCIEX WIFF converter roadmap), and OS support shifts. Always confirm against the current documentation for the exact tool version you are running before committing a pipeline. If you spot something out of date, please open a PR.

Caveats

  • "Native" here means the tool opens the format without a separate conversion step. It does not promise every acquisition mode (DDA, DIA/PASEF, MS3, ion mobility) is equally supported - check the tool's mode-specific docs.
  • For πŸŽ“ and πŸ’° tools, check which formats and features are included in your edition and licensed modules.
  • Converting to mzML is safe and universal, but it can be lossy or bulky for ion-mobility data; for timsTOF, prefer keeping native .d when the tool supports it.
  • This page focuses on bottom-up discovery tools. Targeted (SRM/PRM) and top-down workflows have their own tooling and compatibility quirks.

This guide reflects the author's experience as of the last reviewed date. Spot an error or something out of date? Open a Discussion or update PR - guides are meant to be refreshed. When experts genuinely disagree and cannot reconcile, we also welcome competing guides.

esc

↑ ↓ move Β· ↡ openAll results on the browse page β†’